The low temperature constant temperature and humidity test chamber will inevitably have some failures during the long-term use. For example, what should I do if the compressor pressure is insufficient? At this time, don't be at a loss, then Xiaobian will share some low temperature constant temperature and humidity. Causes and solutions for insufficient compressor pressure in the test chamber.

When there is insufficient pressure in the low-temperature constant-temperature and humidity-test chamber compressor, the first thing to realize is whether the amount of gas used in the factory suddenly increases. Is there any air leakage in the post-treatment pipeline? When this happens, it must be checked from the periphery, from the outside to the inside, from simple to complex inspection of various components.

Then check whether the internal pipeline of the compressor of the low temperature constant temperature and humidity test chamber is unblocked, and there is no blockage. Check air filter, belt, pressure sensor, piston, unload solenoid valve, anti-proportional tolerance valve, etc. are intact. The control line is intact, as well as the diaphragm of the bleeder valve. The specific situation should be excluded one by one to solve the problem.